-66-
Revision 7/F3512
© Moffat Ltd, January 2005
E35 Turbofan Ovens
APPENDIX C. MOTOR CONTROL AND STEAM TIMER
ADJUSTMENT GUIDE
FS Series Timers—Settings E35 Convection Oven (Figure C.1)
Note:
Superceded by FE series timers—see below.
Timer Type Function Time Adjust Setting Actual Time
T1 FSF3 Fan motor direction 0.15 1.5 minutes
T2 FSD3 Steam time 0.3 10 seconds
T3 FSD3 Fan delay 0.3 10 seconds
T4 FSD3 Steam time 0.3 10 seconds
T5 FSD3 Fan delay 0.3 10 seconds
FE Series Timers—Settings E35 Convection Oven (Figure C.2)
Note:
Supercedes FS series timers.
FE series timers interchangeable with earlier FS series timers (above). Time scale settings as per listing
below.
Timer Type Function Scale Setting Time Adjust Setting Actual Time
T1 FEF3T Fan motor direction 10 minutes 0.15 1.5 minutes
T2 FED3T Steam time 10 seconds 1.0 10 seconds
T3 FED3T Fan delay 10 seconds 1.0 10 seconds
T4 FED3T Steam time 10 seconds 1.0 10 seconds
T5 FED3T Fan delay 10 seconds 1.0 10 seconds
Figure C.1
Figure C.2